Read Our Success Stories Related to Pharmaceutical, Food & Beverage and Metal & Mining etc.
C G & Pharmaceutical Pvt Ltd
This includes tunnel upgradation, cold chamber, automation system for ampules manufacturing tank, stability chamber etc.
View
IPCA Laboratories Ltd (PIPARIA)
This project includes ADAM FBD upgradation, Water system panel upgradation for loop 2 and loop 1 Rapid mixer granulator
View
IPCA Laboratories Ltd (ATHAL)
This project includes Air compressor, ADAM FBD upgradation (8 quantity) and Site support for replacing mitsubishi servo drive.
View
IPCA Laboratories Ltd (TARAPUR)
This project includes Conta blender completely new plc panel, Site support for water system fault finding & troubleshooting etc.
View
Micro Labs Ltd (GOA)
This project Site support for sejong coating machine, Octa blender panel upgradation, Sejong machine SCADA upgradation (4 quantities)
View
Micro Labs LTS (BANGALORE)
This project includes Conta blender hmi upgradation (3 quantities), Cartening machine hmi upgradation, Site support for tapasya blender (4 quantities)
View
Ashish Lifescience Pvt Ltd
This project includes Site support for bms system, Chiller integration in existing SCADA of bms system, Site support for machine fabric autoclaim SCADA
View
SUN FRESH AGRO PVT LTD (VASHI)
This project included the machine upgradation of milk pouch filling machine with new PLC and HMI system
ViewCiron Drugs & Pharmaceutical Pvt Ltd
Project Completed On: Jan 2020
SYSTEM DRAWBACKS :
- PLC & HMI both outdated
- No security System
| Old System Specification | New System Specification |
|---|---|
| NO SCADA | 21 CFR PART-11 SCADA |
| OPERATIONS CONTROLLED THROUGH HMI | OPERATIONS MONITORED THROUGH SCADA |
| NO REPORT GENERATION | REPORTS GENERATED |
| NO DATA STORAGE | DATA STORAGE |
Project Completed On: Oct 2020
| Old System Specification | New System Specification |
|---|---|
| MANUAL OPERATION | SCADA BASED OPERATION |
| MANUAL CONTROL PANEL | 21CFR PART 11 CONTROL PANEL |
| NO REPORT GENERATION | REPORT GENERATION |
| NO TEMPERATURE RECORDED | TEMPERATURE RECORDED |
| NO SMS SYSTEM | SMS SYSTEM |
Project Completed On: Oct 2020
FULL NEW SYSTEM WITH OEM COLLABORATION PROVIDED TO BRIGHT PHARMA OEM SCOPE :
- Provided Manufacturing Vessel Tank
AVANEW SCOPE :
- 21 CFR PART-11 SCADA FOR MONITORING & CONTROL
- PLC CONTROL PANEL FOR CONTROLLING MANUFACTURING VESSEL
- PLC: SIEMENS 200 SYSTEM
- LOAD CELL FOR MANUFACTURING & CONTROL
- TANK: 450 LITRES
- 485 PROTOCOL USED
Project Completed On: Oct 2020
| Old System Specification | New System Specification |
|---|---|
| NO SCADA | 21 CFR PART-11 SCADA |
| OPERATIONS CONTROLLED THROUGH HMI | OPERATIONS MONITORED THROUGH SCADA |
| NO REPORT GENERATION | REPORTS GENERATED |
| NO DATA STORAGE | DATA STORAGE |
Project Completed On: Nov 2019
| Old System Specification | New System Specification |
|---|---|
| JAVA BASED SCADA | WEB BASED SCADA |
| NOT FUNCTIONING PROPERLY | MONITORING & CONTROLLING THROUGH SCADA |
| NO REPORTS | REPORTS GENERATED |
Project Completed On: Ongoing
Project Completed On: Aug 2020
| Old System Specification | New System Specification |
|---|---|
| NO SCADA | SCADA PROVIDED |
| NO REPORTS GENERATED | REPORTS GENERATION DONE |
| OPERATION CONTROLLED THROUGH HMI ONLY | |
| NO DATA STORED | DATA STORED |
| NO SMS SYSTEM | SMS SYSTEM |
Project Completed On: Ongoing
SYSTEM DETAILS:
- PLC: MICROLOGIX 1200
- HMI: PANEL 500
IPCA Laboratories Ltd (PIPARIA)
Project Completed On: Jan 2020
| Old System Specification | New System Specification |
|---|---|
| PLC: ABB SYSTEM 550 | PLC: SIEMENS S200 |
| HMI: ABB | HMI: SIEMENS KTP400 |
| NO REPORTS GENERATED | ONLINE REPORTS GENERATION |
| OUT DATED SYSTEM | CONTROL PANEL NOT REPLACED |
| OPERATION ISSUE (TOUCH SCREEN NOT WORKING PROPERLY) |
Project Completed On: Oct 2020
SYSTEM DRAWBACKS :
- DUMP VALVE OPERATION ON WATER CONDUCTIVITY ONLY
USER REQUIREMENTS:
- DUMP VALVE OPERATION ON CONDUCTIVITY AS WELL AS ON TOC HIGH LIMIT
- SECURITY SYSTEM
| Old System Specification | New System Specification |
|---|---|
| PLC: ABB 550 | PLC: EXISTING PLUS ADDED DELTA PLC FOR TOC LOGIC |
| HMI: MITSUBISHI E300 | BOTH PLC’S COMMUNICATION TO A SINGLE HMI |
| NO REPORTS GENERATED | HMI: MITSUBISHI GS2107 |
| NO SECURITY SYSTEM | REPORTS GENERATED |
| SECURITY SYSTEM AS PERS USER GROUPS & USER |
Project Completed On: Oct 2020
User Requirement:
- Security System
| Old System Specification | New System Specification |
|---|---|
| PLC: FX1N MITSUBISHI | PLC: EXISTING |
| HMI: MITSUBISHI E300 | HMI: MITSUBISHI GS2107 |
| NO SECURITY SYSTEM | SECURITY SYSTEM AS PER USER GROUPS & USER |
Project Completed On: Oct 2020
User Requirement:
- Security System
| Old System Specification | New System Specification |
|---|---|
| PLC: ALLEN BRADELY 1400 | EXISTING PLC & HMI |
| HMI: PANEL 700 | SECURITY SYSTEM SCRIPTING TO EXISTING HMI |
IPCA Laboratories Ltd (ATHAL)
Project Completed On: Feb 2020
| Old System Specification | New System Specification |
|---|---|
| CHINESE MAKE PLC WITH HMI DISPLAY | PLC: SIEMENS S7 200 |
| OUTDATED SYSTEM, NOT INWORKING CONDITION | HMI: SIEMENS KTP 700 |
| VFD USED FOR MONITORING TEMPERATURE, PRESSURE & AIR FLOW SPEED | |
| REPORT GENERATION WITH THE PARAMETERS | |
| SECURITY SYSTEM AS PER USER GROUP & USER |
Project Completed On: April 2020
MACHINE NAME: FBD (200KG) (Quantity 4)
| Old System Specification | New System Specification |
|---|---|
| PLC: MITSUBISHI FX 1N-14MR | PLC: EXISTING |
| HMI: MITSUBISHI E300 | HMI: MITSUBSHI GS2107 |
| LIMITATION TO RECIPE | RECIPE UPTO 50 |
| NO SECURITY SYSTEM | SECURITY SYSTEM AS PER USER GROUPS & USER |
| NO REPORT GENERATION | ONLINE REPORT GENERATION |
MACHINE NAME: FBD (100KG) (Quantity 3)
| Old System Specification | New System Specification |
|---|---|
| PLC: MITSUBISHI FX 1N-14MR | PLC: EXISTING |
| HMI: MITSUBISHI E300 | HMI: MITSUBSHI GS2107 |
| LIMITATION TO RECIPE | RECIPE UPTO 50 |
| NO SECURITY SYSTEM | SECURITY SYSTEM AS PER USER GROUPS & USER |
| NO REPORT GENERATION | ONLINE REPORT GENERATION |
Project Completed On: June 2020
PROJECT DETAILS:
| Old System Specification | New System Specification |
|---|---|
| PLC: DELTA DVP 16ES2 | PLC: EXISTING |
| HMI: DELTA TP02 | HMI: MITSUBSHI GS2107 |
| LIMITATION TO RECIPE | RECIPE UPTO 50 |
| NO SECURITY SYSTEM | SECURITY SYSTEM AS PER USER GROUPS & USER |
| NO REPORT GENERATION | ONLINE REPORT GENERATION |
Project Completed On: June 2020
PROJECT DETAILS:
- MODEL NO: HFKE 13 WITH MATERIAL
IPCA Laboratories Ltd (TARAPUR)
| Old System Specification | New System Specification |
|---|---|
| MANUAL CONTROL PANEL | PLC CONTROL PANEL |
| OPERATIONS THROUGH BUTTONS & RELAY LOGIC |
PLC: SIEMENS S7 200 HMI: KTP 700 COMFORT |
| NO HMI DISPLAY | OPERATIONS CONTROLLED THROUGH PLC |
| NO AUTO CYCLE/ OPERATIONS | AUTO AS WELL AS MANUAL OPERATIONS |
| NO REPORTS GENERATED | REPORTS GENERATED |
| NO DATA STORAGE | DATA STORAGE |
| NO SECURITY SYSTEM | SECURITY SYSTEM AS PER USER GROUP & USER |
SYSTEM DETAILS:
- PLC: SIEMENS 1200
- HMI: SCHNEIDER
USER REQUIREMENTS:
- SIP CYCLE NOT WORKING PROPERLY
SYSTEM DETAILS:
- PLC: SIEMENS S7 200
- HMI: KTP 400
USER REQUIREMENTS:
- AUTO LOGIC NOT WORKING PROPERLY
USV Ltd (Daman)
PROJECT DETAILS:
- PLC: FX 1N
- HMI: MITSUBISHI E300
USER REQUIREMENTS::
- AUTO LOGIC NOT WORKING PROPERLY
| Old System Specification | New System Specification |
|---|---|
| HMI: BEIJER 1X PRO | HMI: X2 PRO |
Micro Labs Ltd (Goa)
Project Completed On: September 2020
PROJECT SPECIFICATIONS:
- PLC: SIEMENS S7 300
- IPC LABVIEW, SACS 2.1
USER REQUIREMENTS:
- SIP CYCLE NOT WORKING PROPERLY
- SUPPLY TEMPERATURE NOT MAINTAINED WITHIN LIMIT
Project Completed On: October 2020
SYSTEM DRAWBACKS:
- SCADA NOT FUNCTIONING PROPERLY
- LICENSE EXPIRED
- IPC SHUTDOWN AUTOMATICALLY
USER REQUIREMENTS:
- REQUIRED ONLINE PRITING
- OPERATION CONTROLLED THROUGH HMI
| Old System Specification | New System Specification |
|---|---|
| PLC: MICROLOGIX 1400 | PLC: EXISTING |
| SCADA: ROCKWELL | HMI: MITSUBISHI GS2110 |
| NO ONLINE REPORTS GENERATED | ONLINE REPORTS GENERATED |
| NO SECURITY SYSTEM | SECURITY SYSTEM AS PER USER GROUP & USER |
| NO DATA STORAGE | DATA STORAGE |
Project Completed On: Jan 2021
SYSTEM DRAWBACKS:
- FREQUENTLY ISSUES OCCURING IN SCADA SYSTEM
USER REQUIREMENTS:
- REQUIRED FLAME PROOF IPC
- CUSTOMIZED REPORT GENERATION
- 21 CFR PART-11 COMPLY
| Old System Specification | New System Specification |
|---|---|
| PLC: SIEMENS S7 300 | PLC: EXISTING |
| IPC: PROFACE | IPC: WINMATE |
| SCADA: LABVIEW, SACS 2.1 | SCADA: INDUSOFT WEB BASED SCADA |
| 21 CFR PART-11 COMPLY |
Micro Labs Ltd (Bangalore)
SYSTEM DRAWBACK:
- HMI KEYS/BUTTONS NOT WORKING PROPERLY
- HMI DISPLAY IS TOO SMALL FOR OPERATING
- OUTDATED HMI
USER REQUIREMENTS:
- REQUIRED HMI WITH BIGGER DISPLAY
- REQUIRED SECURITY SYSTEM AS PER USER GROUP & USER
| Old System Specification | New System Specification |
|---|---|
| PLC: MICROLOGIX 1400 | PLC: EXISTING |
| HMI: PANEL VIEW 400 | HMI: MITSUBISHI GS2107 |
| NO REPORTS GENERATED | REPORTS GENERATED |
| NO SECURITY SYSTEM | SECURITY SYSTEM AS PER USER GROUP & USER |
SYSTEM DRAWBACK:
- HMI GLASS DAMAGED
- OUTDATED HMI
- RECIPE FUNCTION NOT AVAILABLE
USER REQUIREMENTS:
- NEW HMI WITH SECURITY SYSTEM
- REQUIRED RECIPE FUNCTION
| Old System Specification | New System Specification |
|---|---|
| PLC: MICROLOGIX 1500 | PLC: EXISTING |
| HMI: EXOR UNIOP ETOP 06 | HMI: MITSUBISHI GS2107 |
| NO RECIPE FUNCTION | RECIPE FUNCTION PROVIDED |
| NO SECURITY | SECURITY SYSTEM AS PER USER GROUP & USER |
SYSTEM DRAWBACKS:
- AUTOCYCLE NOT WORKING PROPERLY
- HOOTER ACKNOWLEDGE BUTTON NOT PROVIDED
SYSTEM DETAILS:
- PLC: SIEMENS 1200
- HMI: KTP 900 COMFORT
Ashish Lifescience Pvt Ltd
SYSTEM DETAILS:
- VFD OPERATIONS WORKING MANUALLY
- NO REPORT GENERATION FOR VFD FREQUENCY
USER REQUIREMENTS:
- VFD FREQUENCY SET & VIEW FOR INDIVIDUAL AHU FROM SCADA
- REPORT GENERATION OF VFD FREQUENCY
- NIGHT MODE SCRIPTING ADDED IN SCADA
SYSTEM DETAILS:
- CHILLER: CARRIER
- SCADA: INDUSOFT
- PROTOCOL USED: MODBUS
SYSTEM DRAWBACKS:
- CHILLER DATA NOT CAPTURED IN SCADA
USER REQUIREMENTS:
- CHILLER DATA REQUIRED IN SCADA FOR VIEW & CONTROL PURPOSE
- CHILLER CONTROLLING FROM SCADA
- REPORT GENERATION OF CHILLER PARAMETERS
SYSTEM DETAILS:
- SCADA CORRUPTED
USER REQUIREMENTS:
- REINSTALL THE SCADA WITH INSTALLATION & COMMISSIONING
SUN FRESH AGRO PVT LTD (VASHI)
SYSTEM DRAWBACKS:
- MANUAL OPERATIONS NOT WORKING PROPERLY
- MAINTENANCE IS HIGH
USER REQUIREMENTS::
- WANTED TO UPGRADE FROM MANUAL TO AUTOMATED
- HMI Data Storage
| Old System Specification | New System Specification |
|---|---|
| Manual Operations | PLC based Operations |
| Operated through buttons | Operated through HMI |
| PLC: SIEMENS S7 200 | |
| HMI: KTP 400 |